Skip to content
Medium Open Electronics & Screen

Heated bed fails to reach temperature

Some Neptune 4 Plus units abort prints with a 'heater_bed not heating at expected rate' error. Elegoo has a troubleshooting page for heated bed heating failure on the ribbon-cable 4 Plus and 4 Max, and the causes it lists include a room below 25 °C and the rear auxiliary fan running before the bed reaches temperature. A wrong setting on the 115/230 V selector can also stop the bed heating.

What fixes it

Keep the rear fan off until the bed is at temperature, use an enclosure in a cold room, check the recessed 115/230 V selector with the printer unplugged, and inspect the fuse, bed harness, thermistor connector and heater terminals.

Log in to confirm this happens to you 0 owners confirmed

Workarounds (0)

No workarounds posted yet.

Comments (0)