Heavy purge waste and hard-to-tune flush settings
Multicolor prints throw away a lot of filament: Tom's Hardware reported 730 g wasted on supports, purge tower and poop for a 312 g model. The purge amount cannot be set in the slicer, only on the touchscreen during a print, and there is no option to flush into a purge object. Setting flush too low causes color bleeding.
What fixes it
Adjust purge on the touchscreen during the print, and do not set it too low or colors bleed. No slicer-side fix is reported.